{"id":6685,"date":"2026-01-22T17:05:51","date_gmt":"2026-01-22T17:05:51","guid":{"rendered":"https:\/\/watford-engineering.com\/home\/florida-am-references-copy\/"},"modified":"2026-01-22T20:49:53","modified_gmt":"2026-01-22T20:49:53","slug":"reference-project-florida-am-univesity-2","status":"publish","type":"post","link":"https:\/\/watford-engineering.com\/home\/reference-project-florida-am-univesity-2\/","title":{"rendered":"Northwest Florida State University"},"content":{"rendered":"<!--themify_builder_content-->\n<div id=\"themify_builder_content-6685\" data-postid=\"6685\" class=\"themify_builder_content themify_builder_content-6685 themify_builder tf_clear\">\n    \t\t\t\t<div  data-parallax-bg=\"desktop\" data-css_id=\"3fi1072\" data-lazy=\"1\" class=\"module_row themify_builder_row fullwidth_row_container tb_3fi1072 tb_first tf_w\">\n\t\t\t\t\t\t<div class=\"row_inner col_align_top tb_col_count_1 tf_box tf_rel\">\n\t\t\t\t\t\t<div  data-lazy=\"1\" class=\"module_column tb-column col-full tb_gxok021 first\">\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<div  data-parallax-bg=\"desktop\" data-css_id=\"8k5i110\" data-lazy=\"1\" class=\"module_row themify_builder_row fullwidth_row_container tb_8k5i110 tf_w\">\n\t\t\t\t\t\t<div class=\"row_inner col_align_top tb_col_count_3 tf_box tf_rel\">\n\t\t\t\t\t\t<div  data-lazy=\"1\" class=\"module_column tb-column col3-1 tb_ijn2660 first\">\n\t\t\t\t\t<!-- module text -->\n<div  class=\"module module-text tb_171p107   \" data-lazy=\"1\">\n\t    <div  class=\"tb_text_wrap\">\n\t\t<h2 style=\"text-align: center;\">\u00a0<\/h2>    <\/div>\n<\/div>\n<!-- \/module text --><!-- module image -->\n<div  class=\"module module-image tb_fmu6702 image-top   tf_mw\" data-lazy=\"1\">\n        <div class=\"image-wrap tf_rel tf_mw\">\n\t\t    <img loading=\"lazy\" decoding=\"async\" width=\"560\" height=\"560\" src=\"https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NVAdminBldg310_02-1.png\" class=\"wp-post-image wp-image-5961\" title=\"NVAdminBldg310_02-1\" alt=\"NVAdminBldg310_02-1\" srcset=\"https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NVAdminBldg310_02-1.png 560w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NVAdminBldg310_02-1-300x300.png 300w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NVAdminBldg310_02-1-150x150.png 150w\" sizes=\"auto, (max-width: 560px) 100vw, 560px\" \/>\t\n\t\t<\/div>\n\t<!-- \/image-wrap -->\n    \n    \t<\/div>\n<!-- \/module image -->\t\t<\/div>\n\t\t\t\t\t<div  data-lazy=\"1\" class=\"module_column tb-column col3-1 tb_nzs3960\">\n\t\t\t\t\t<!-- module text -->\n<div  class=\"module module-text tb_azkh276   \" data-lazy=\"1\">\n\t    <div  class=\"tb_text_wrap\">\n\t\t<h2 style=\"text-align: center;\">Northwest Florida State College<\/h2>    <\/div>\n<\/div>\n<!-- \/module text --><!-- module image -->\n<div  class=\"module module-image tb_al0s098 image-top   tf_mw\" data-lazy=\"1\">\n        <div class=\"image-wrap tf_rel tf_mw\">\n\t\t    <img loading=\"lazy\" decoding=\"async\" width=\"1703\" height=\"1703\" src=\"https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NWFSC-Building-420-1-scaled-1.jpg\" class=\"wp-post-image wp-image-5958\" title=\"NWFSC-Building-420-1-scaled\" alt=\"NWFSC-Building-420-1-scaled\" srcset=\"https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NWFSC-Building-420-1-scaled-1.jpg 1703w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NWFSC-Building-420-1-scaled-1-300x300.jpg 300w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NWFSC-Building-420-1-scaled-1-1024x1024.jpg 1024w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NWFSC-Building-420-1-scaled-1-150x150.jpg 150w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NWFSC-Building-420-1-scaled-1-768x768.jpg 768w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NWFSC-Building-420-1-scaled-1-1536x1536.jpg 1536w\" sizes=\"auto, (max-width: 1703px) 100vw, 1703px\" \/>\t\n\t\t<\/div>\n\t<!-- \/image-wrap -->\n    \n    \t<\/div>\n<!-- \/module image --><!-- module text -->\n<div  class=\"module module-text tb_to47706   \" data-lazy=\"1\">\n\t    <div  class=\"tb_text_wrap\">\n\t\t<p data-start=\"809\" data-end=\"853\">Watford Engineering provided mechanical, plumbing, and fire protection engineering services for multiple facilities at Northwest Florida State College. These projects included new construction, building additions, and renovations to existing academic and student services facilities, requiring coordination with existing systems and ongoing campus operations.<\/p>\n<h3 data-start=\"809\" data-end=\"853\">\u00a0<\/h3>\n<h3 data-start=\"809\" data-end=\"853\">Building 310 \u2013 Addition and Renovation<\/h3>\n<p data-start=\"854\" data-end=\"1219\">Watford Engineering supported the addition of a second level to an existing single-story building. As part of the project, all existing first-floor HVAC systems were demolished and replaced with new chilled water variable air volume air handling units serving each floor. Terminal units with hot water reheat were utilized to provide zone-level temperature control.<\/p>\n<p data-start=\"1221\" data-end=\"1495\">Plumbing work included new water heaters to serve building fixtures, and a new fire sprinkler system was added throughout the facility. Roof drainage systems were extended and connected to the site stormwater infrastructure.<\/p>\n<p data-start=\"1221\" data-end=\"1495\"><strong data-start=\"1448\" data-end=\"1495\">19,000 SF | $4.2 million construction value<\/strong><\/p>\n<h3 data-start=\"1497\" data-end=\"1546\">\u00a0<\/h3>\n<h3 data-start=\"1497\" data-end=\"1546\">Building 400 \u2013 Student Services Renovations<\/h3>\n<p data-start=\"1547\" data-end=\"1929\">Watford Engineering provided HVAC and plumbing engineering services for renovations to the second and third floors of the existing Student Services Building. The scope included redistribution of airflow from existing terminal units, associated minor controls modifications, relocation of fire sprinkler heads to accommodate a new ceiling grid, and plumbing service for new fixtures.<\/p>\n<p data-start=\"1931\" data-end=\"2162\">The design included full air balancing for both floors. Watford Engineering also provided commissioning services for the HVAC controls systems to verify proper operation following construction.<\/p>\n<p data-start=\"1931\" data-end=\"2162\"><strong data-start=\"2127\" data-end=\"2162\">33,700 SF | $2.7 million construction value<\/strong><\/p>\n<h3 data-start=\"2164\" data-end=\"2223\">\u00a0<\/h3>\n<h3 data-start=\"2164\" data-end=\"2223\">Building 420 \u2013 Allied Health Renovations and Addition<\/h3>\n<p data-start=\"2224\" data-end=\"2530\">Watford Engineering provided professional engineering design services for the renovation and expansion of the existing Allied Health (Nursing) Building. The project included HVAC system upgrades with new systems and digital controls, minor upgrades to existing plumbing systems, and fire protection design.<\/p>\n<p data-start=\"2532\" data-end=\"2788\">In addition to renovations, the project included a 10,000 square foot addition to the original single-story facility, expanding instructional and support spaces while integrating new systems with existing infrastructure.<\/p>\n<p data-start=\"2532\" data-end=\"2788\"><strong data-start=\"2755\" data-end=\"2788\">88,000 SF total building area<\/strong><\/p>    <\/div>\n<\/div>\n<!-- \/module text -->\t\t<\/div>\n\t\t\t\t\t<div  data-lazy=\"1\" class=\"module_column tb-column col3-1 tb_rm7g600 last\">\n\t\t\t\t\t<!-- module text -->\n<div  class=\"module module-text tb_hjc9060   \" data-lazy=\"1\">\n\t    <div  class=\"tb_text_wrap\">\n\t\t<h2 style=\"text-align: center;\">\u00a0<\/h2>    <\/div>\n<\/div>\n<!-- \/module text --><!-- module image -->\n<div  class=\"module module-image tb_1kic992 image-top   tf_mw\" data-lazy=\"1\">\n        <div class=\"image-wrap tf_rel tf_mw\">\n\t\t    <img loading=\"lazy\" decoding=\"async\" width=\"607\" height=\"607\" src=\"https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/campus20scenes20059-edit-web.jpg\" class=\"wp-post-image wp-image-5986\" title=\"campus20scenes20059-edit-web\" alt=\"campus20scenes20059-edit-web\" srcset=\"https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/campus20scenes20059-edit-web.jpg 607w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/campus20scenes20059-edit-web-300x300.jpg 300w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/campus20scenes20059-edit-web-150x150.jpg 150w\" sizes=\"auto, (max-width: 607px) 100vw, 607px\" \/>\t\n\t\t<\/div>\n\t<!-- \/image-wrap -->\n    \n    \t<\/div>\n<!-- \/module image -->\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t<\/div>\n<!--\/themify_builder_content-->","protected":false},"excerpt":{"rendered":"<p>\u00a0<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[29],"tags":[48,21,55,49,43,58,52,36,50,51,56,57,20,54,53,42,44,47,46,35,37],"class_list":["post-6685","post","type-post","status-publish","format-standard","hentry","category-reference-project","tag-design-engineering","tag-electrical-engineering","tag-elementary-school-design","tag-facility-design-services","tag-fire-protection-engineering","tag-florida","tag-grand-ridge-florida","tag-inc","tag-jackson-county-school-board","tag-jackson-county-school-system","tag-marianna","tag-marianna-florida","tag-mechanical-engineering","tag-north-west-florida","tag-panhandle-florida","tag-plumbing-engineering","tag-professional-consulting","tag-professional-design-services","tag-professional-engineering","tag-watford-engineering","tag-wei","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author",""],"builder_content":"<h2 style=\"text-align: center;\">\u00a0<\/h2>\n<img src=\"https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NVAdminBldg310_02-1.png\" title=\"NVAdminBldg310_02-1\" alt=\"NVAdminBldg310_02-1\" srcset=\"https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NVAdminBldg310_02-1.png 560w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NVAdminBldg310_02-1-300x300.png 300w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NVAdminBldg310_02-1-150x150.png 150w\" sizes=\"(max-width: 560px) 100vw, 560px\" \/>\n<h2 style=\"text-align: center;\">Northwest Florida State College<\/h2>\n<img src=\"https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NWFSC-Building-420-1-scaled-1.jpg\" title=\"NWFSC-Building-420-1-scaled\" alt=\"NWFSC-Building-420-1-scaled\" srcset=\"https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NWFSC-Building-420-1-scaled-1.jpg 1703w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NWFSC-Building-420-1-scaled-1-300x300.jpg 300w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NWFSC-Building-420-1-scaled-1-1024x1024.jpg 1024w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NWFSC-Building-420-1-scaled-1-150x150.jpg 150w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NWFSC-Building-420-1-scaled-1-768x768.jpg 768w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/NWFSC-Building-420-1-scaled-1-1536x1536.jpg 1536w\" sizes=\"(max-width: 1703px) 100vw, 1703px\" \/>\n<p data-start=\"809\" data-end=\"853\">Watford Engineering provided mechanical, plumbing, and fire protection engineering services for multiple facilities at Northwest Florida State College. These projects included new construction, building additions, and renovations to existing academic and student services facilities, requiring coordination with existing systems and ongoing campus operations.<\/p> <h3 data-start=\"809\" data-end=\"853\">\u00a0<\/h3> <h3 data-start=\"809\" data-end=\"853\">Building 310 \u2013 Addition and Renovation<\/h3> <p data-start=\"854\" data-end=\"1219\">Watford Engineering supported the addition of a second level to an existing single-story building. As part of the project, all existing first-floor HVAC systems were demolished and replaced with new chilled water variable air volume air handling units serving each floor. Terminal units with hot water reheat were utilized to provide zone-level temperature control.<\/p> <p data-start=\"1221\" data-end=\"1495\">Plumbing work included new water heaters to serve building fixtures, and a new fire sprinkler system was added throughout the facility. Roof drainage systems were extended and connected to the site stormwater infrastructure.<\/p> <p data-start=\"1221\" data-end=\"1495\"><strong data-start=\"1448\" data-end=\"1495\">19,000 SF | $4.2 million construction value<\/strong><\/p> <h3 data-start=\"1497\" data-end=\"1546\">\u00a0<\/h3> <h3 data-start=\"1497\" data-end=\"1546\">Building 400 \u2013 Student Services Renovations<\/h3> <p data-start=\"1547\" data-end=\"1929\">Watford Engineering provided HVAC and plumbing engineering services for renovations to the second and third floors of the existing Student Services Building. The scope included redistribution of airflow from existing terminal units, associated minor controls modifications, relocation of fire sprinkler heads to accommodate a new ceiling grid, and plumbing service for new fixtures.<\/p> <p data-start=\"1931\" data-end=\"2162\">The design included full air balancing for both floors. Watford Engineering also provided commissioning services for the HVAC controls systems to verify proper operation following construction.<\/p> <p data-start=\"1931\" data-end=\"2162\"><strong data-start=\"2127\" data-end=\"2162\">33,700 SF | $2.7 million construction value<\/strong><\/p> <h3 data-start=\"2164\" data-end=\"2223\">\u00a0<\/h3> <h3 data-start=\"2164\" data-end=\"2223\">Building 420 \u2013 Allied Health Renovations and Addition<\/h3> <p data-start=\"2224\" data-end=\"2530\">Watford Engineering provided professional engineering design services for the renovation and expansion of the existing Allied Health (Nursing) Building. The project included HVAC system upgrades with new systems and digital controls, minor upgrades to existing plumbing systems, and fire protection design.<\/p> <p data-start=\"2532\" data-end=\"2788\">In addition to renovations, the project included a 10,000 square foot addition to the original single-story facility, expanding instructional and support spaces while integrating new systems with existing infrastructure.<\/p> <p data-start=\"2532\" data-end=\"2788\"><strong data-start=\"2755\" data-end=\"2788\">88,000 SF total building area<\/strong><\/p>\n<h2 style=\"text-align: center;\">\u00a0<\/h2>\n<img src=\"https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/campus20scenes20059-edit-web.jpg\" title=\"campus20scenes20059-edit-web\" alt=\"campus20scenes20059-edit-web\" srcset=\"https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/campus20scenes20059-edit-web.jpg 607w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/campus20scenes20059-edit-web-300x300.jpg 300w, https:\/\/watford-engineering.com\/wp-content\/uploads\/2025\/10\/campus20scenes20059-edit-web-150x150.jpg 150w\" sizes=\"(max-width: 607px) 100vw, 607px\" \/>","_links":{"self":[{"href":"https:\/\/watford-engineering.com\/home\/wp-json\/wp\/v2\/posts\/6685","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/watford-engineering.com\/home\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/watford-engineering.com\/home\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/watford-engineering.com\/home\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/watford-engineering.com\/home\/wp-json\/wp\/v2\/comments?post=6685"}],"version-history":[{"count":13,"href":"https:\/\/watford-engineering.com\/home\/wp-json\/wp\/v2\/posts\/6685\/revisions"}],"predecessor-version":[{"id":6698,"href":"https:\/\/watford-engineering.com\/home\/wp-json\/wp\/v2\/posts\/6685\/revisions\/6698"}],"wp:attachment":[{"href":"https:\/\/watford-engineering.com\/home\/wp-json\/wp\/v2\/media?parent=6685"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/watford-engineering.com\/home\/wp-json\/wp\/v2\/categories?post=6685"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/watford-engineering.com\/home\/wp-json\/wp\/v2\/tags?post=6685"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}